EU IVDR CE Marking: Requirements & Legacy Deadlines
Last reviewed:
Plan IVDR conformity assessment and CE marking using the applicable class, performance evidence, quality system and registration requirements.
EU IVDR CE marking: qualification and route
The EU IVDR governs covered in vitro diagnostic devices. Use this guide for CE marking within that framework. Start by documenting intended purpose, analyte/marker, specimen, population, clinical function, operator and setting. Confirm that the product qualifies as an IVD, then apply Annex VIII classification under the IVDR.
| Class | Notified Body involvement | Key planning point |
|---|---|---|
| A non-sterile | Generally self-declaration | Complete technical documentation, QMS and applicable obligations still apply |
| A sterile | Limited to establishing, securing and maintaining sterile conditions | Do not describe this as the same review as Classes B–D |
| B and C | Applicable Notified Body conformity assessment | Performance evidence and QMS readiness are central |
| D | Higher-risk assessment with additional applicable procedures | Assess reference-laboratory, batch-testing and expert requirements as applicable |
Confirm the body’s IVDR designation and device scope using Notified Body selection. Certification by an ISO auditor alone is not IVDR conformity assessment.
Evidence and documentation before marking
Map the applicable Annex I GSPRs to controlled evidence. Prepare Annex II/III technical documentation, risk management, labeling and a performance-evaluation plan/report addressing scientific validity, analytical performance and clinical performance. The PER guide explains those separate elements.
Implement the Article 10 QMS, PRRC, EU AR where needed, supply-chain controls, UDI and applicable registration. ISO 13485 is a common QMS framework; a certificate does not replace all IVDR duties. Class A non-sterile is not exempt from a functioning QMS.
Complete the applicable conformity assessment and obtain required certificates. The manufacturer then finalizes and signs the EU Declaration of Conformity before affixing CE marking. Use the Notified Body identification number where required and complete EUDAMED registration under the applicable timing rules.
Legacy IVDs: verify eligibility, not only the end date
Eligible Class D legacy devices may have an end date of December 31, 2027; Class C December 31, 2028; Class B and A sterile December 31, 2029. These depend on Article 110 conditions, including QMS, application and written-agreement milestones, continued directive compliance and restrictions on significant changes.
The Commission transition page and IVDR hub set out the milestones. Class A non-sterile and new devices cannot simply claim the same extension. Continued availability of units already lawfully placed is a different question from placing further units on the market.
Maintain conformity after launch
Operate PMS, PMPF, vigilance and changes under the QMS. Class A/B generally use a PMS Report; Class C/D use an annual PSUR. Update the PER, risk file and labels when evidence changes. Pure Global can coordinate the route, gap assessment, evidence plan and Notified Body preparation within the device’s actual scope.
Start selling your IVD in the European Union
Plan your device registration, local representation and ongoing compliance with Pure Global.

Frequently asked questions
Yes. Self-declaration does not remove the Article 10 QMS or technical-documentation obligations. The system must suit the device and applicable requirements even when a Notified Body is not involved.
No. Notified Body involvement for Class A sterile devices is limited to the aspects relating to establishing, securing and maintaining sterile conditions. Higher classes have different conformity-assessment requirements.
No. Eligibility depends on all applicable Article 110 conditions and intermediate milestones. Retain evidence of QMS, timely application/agreement and other conditions rather than relying only on the final placement date.